What is the minimum size for an egress window?
An emergency escape opening (egress window) needs a net clear opening of at least 5.7 sq ft — 5.0 sq ft at grade — with a minimum height of 24 in, a minimum width of 20 in, and a sill no more than 44 in above the floor (2021 IRC §R310.2). Since 20 × 24 in is only ~3.3 sq ft, at least one dimension must exceed its minimum.
Source: 2021 IRC §R310.2 ·
These are model codes — the edition your jurisdiction has adopted, plus any local amendments, is what governs. Confirm with your AHJ.
An emergency escape and rescue opening — the “egress window” — is what lets you get out, and firefighters get in, through a window. The IRC sizes it four ways (2021 IRC §R310.2):
- Net clear opening area: at least 5.7 sq ft (5.0 sq ft for openings at grade-floor level).
- Net clear opening height: at least 24 inches.
- Net clear opening width: at least 20 inches.
- Sill height: no more than 44 inches above the finished floor.
“Net clear opening” is the actual hole you can climb through with the sash open — not the rough opening or the glass size.
The catch most people miss: the minimums don’t multiply to the area. 20 × 24 inches is only 3.3 sq ft — well under 5.7 — so at least one dimension has to be larger than its minimum to hit the area. A common result is a wider or taller window than the single-dimension minimums suggest.
Where they’re required: every sleeping room, and basements with habitable space (2021 IRC §R310.1). Bars, grilles, or covers are allowed only if they release from the inside without tools or special knowledge (§R310.4). Window wells for below-grade openings have their own size and ladder rules (§R310.2.3). Editions and local amendments vary — verify with your AHJ.
Sources
- ICC Digital Codes — 2021 IRC — §R310.2 (emergency escape and rescue openings — size, sill height)